This kind of Micro-hydro Generator is consisted of an inclined impulse turbine and a set of direct connected AC single-phase / three-phase generator. With the characteristics of small body, lightweight, simple structure, reliable operation and convenient assembly, and serving as the power source of lighting, TVs and recorders, it is most suitable for the households in mountain areas with scattered and small hydroelectric sources.

1684915962695354.png

Microhydropower can be one of the most simple and consistent forms or renewable energy on your property.


If you have water flowing through your property, you might consider building a small hydropower system to generate electricity. Microhydropower systems usually generate up to 100 kilowatts of electricity. Most of the hydropower systems used by homeowners and small business owners, including farmers and ranchers, would qualify as microhydropower systems. But a 10-kilowatt microhydropower system generally can provide enough power for a large home, a small resort, or a hobby farm.


A microhydropower system needs a turbine, pump, or waterwheel to transform the energy of flowing water into rotational energy, which is converted into electricity.

This kind of Micro-hydro Generator is consisted of an inclined impulse turbine and a set of direct connected AC single-phase / three-phase generator. With the characteristics of small body, lightweight, simple structure, reliable operation and convenient assembly, and serving as the power source of lighting, TVs and recorders, it is most suitable for the households in mountain areas with scattered and small hydroelectric sources. 


The consumers can do easily themselves the installation and operation. This product has been thoroughly strengthened in the special technical measures to good quality, stable function and easy operation for women and children. Much less investment may add more happiness to your family.

Model

Power

Headm

Rate of flow

Rotational   Speed

Install tube   diameter

W

m3/s

rpm

mm

CJ-300W

300

12-14

0.003-0.005

1500

50

CJ-500W

500

12-18

0.005-0.007

1500

50-75

CJ-750W

750

14-18

0.005-0.008

1500

75

CJ-1.5KW

1500

18-25

0.008-0.011

1500

125

CJD-1.5KW

1500

15

0.012-0.018

1500

125-150

CJ-3KW

3000

25-35

0.015-0.019

1500

125-150

CJD-3KW

3000

18-20

0.018-0.030

1500

150

CJ-6KW

6000

28-35

0.030-0.038

1500

150-200

CJD-6KW

6000

18-20

0.038-0.050

1000

200

CJ-10KW

10000

30-38

0.040-0.050

1500

200-250

CJD-10KW

10000

25-30

0.050-0.060

1000

200-250

CJD-12KW

12000

28-35

0.050-0.060

1500

200-250

CJD-15KW

15000

30-40

0.060-0.070

1500/1000

200

CJD-20KW

20000

30-45

0.060-0.100

1500/1000

250-300

CJD-30KW

 

30000

38-45

0.090-0.120

1500/1000

250-300

 

The typical micro hydro generator station is as follows (figure 1),which consists of earthwork(inlet conduit construction,unit room and drain etc),the micro hydro generator,electrical wires and the users wires.

13.jpg

 

 

 

01

Penstock

06

Inlet Pipe

11

User

02

Reservoir

07

Tailrace

h

Water head

03

Trash rack

08

Power house

h1

Penstock fall

04

Fore bay

09

Electric pole

h2

Flood altitude

05

Brook

10

Wire

H

Reach fall

The work process is as followsCollecting the water of stream by reservior,the water inflow the pressure poor through the inlet conduit,the go into th micro hydro generator which is installed in the unit room through the inlet pipeline,force the runner to circumgyate,which drives the genertator to generate electricity.At eh same time,the adjustment machine autoadjust the voltage and the frequency to meet the requirements for power supply,and then the user can use the electricity transmitted hyelectrical wires.


Operation Method:

1) Firstly, check whether all components are completed and the intake of penstock is blocked.

2) Then check whether the runner of turbine can be easily rotated, and rotated in by hand to ensure the voltage meter has readings (put the output switch in OFF position).

3) For the first starting, the output switch should be put in the voltage-stabilized control position (A), then open the gate to let water out from small to large, observe the readings meter till 230V (380V) or so continue enhancing water volume, the voltage device is reliable if the reading keep still. At this time the load can be connected, then adjust the water volume to hold the output of 230V (380V) or so. Once the stabilizing device break down, put the switch in B, then the voltage of unit will be under manual-controlled, you may follow the next procedure to control by valve.

4) During the operation, the load should be kept stable as possible as can be. Don't shut off the load suddenly, or else the high voltage will burn out the rest load, if you must is connect the load, you may decrease water to small volume at first, then disconnect the most part of load when the voltage has dropped to below 380v (you must do as this even you run the unit under the using of voltage-stabilizing device).

5) It need only close the valve to switch off the unit when the load has been stable after first operation, the power switch may hold on so that you may adjust voltage up to 230V (380V)  directly for next running.                                          

Maintenance:

1) To check and clean the mud and foreign material blocking in the intake house and trash rack.

2) The frame of unit should be injected water-proof grease by using grease cup in every three month, each time rotating for three times. The upper bearing also should be added waterproof grease for every six months.

3) The generator must be conducted the dry treatment before next start if it became wet.